Function: Systems waste incinerator used to process destroys wastes conventional industrial and hazardous medical waste in all 3 solid, liquid, sludge not worth recycling or re use, capable of burning fire with two-level methods at high temperatures.
Technology: rotary drum incinerator multilevel DTC-1000
Capacity: 1000 kg / hour, continuous operation 24 hours / day
Process explanation:
Intermediate garbage storage
These types of waste to be burned will be put into Kr garbage storage. Then the garbage is transferred from the Kr warehouse into the incinerator completely automatically by the Cr garbage feeder.
Equipment loaded garbage
Rubbish from the depot was put into the garbage load bin Kr automatically and through cable transmission on intermediate hopper at the top of the combustion chamber as a primary. Then, open combustion chamber beginning to put rubbish in.
Primary combustion chambers
Primary Chamber designed rotating drum, garbage in the combustion chamber are continuously mixed Island, so the burning process and stabilize the temperature in the primary Chamber. To maintain a stable temperature in the primary Chamber approximately from 650-1000oC operators will use the temperature control device, control the level of garbage litter load loading into the primary Chamber and control oil burners DO.
The secondary combustion chamber
Secondary chamber temperatures are maintained at approximately 1.050-1.300oC by the secondary burner. Thanks to the high temperature, the mixing, shuffling and time saving gas in a secondary chamber long enough (> 2 seconds) to ensure smoke containing hazardous waste (especially dioxins, furans) and odors are destroyed completely.
Extra the secondary combustion chamber: To ensure stability and compensation for losses as well as other impacts when handling hazardous wastes requires high. In the system, additional secondary combustion chambers are added to provide thermal stability by the oil burner D3.
Heat storage chamber
The storage chamber is where the exhaust gas in the secondary combustion chamber passes through, the heavy gas insulating should continue to be burned, extending the duration of the fire.
Waste heat exchanger
Heat exchangers reduce exhaust temperatures with high temperatures from 1300oC to <300oC.
Cylon separates dust
So emissions through cyclone equipment will be separated by about 60 - 70% of ash and dust. Waste gas is separated from ash and dust through HT absorption tower. The ash is separated from the exhaust gas and the ash removal device (VT2) is continuously removed from the cyclone and transported to the ash store by the screw conveyor.
Absorption tower
Emission through cyclone enters the absorption tower in contact with the absorption solution (NaOH or Ca (OH) 2) mist spraying from the cooling tank. The exhaust gases (SO2, HF, HCl ...) will be absorbed by the solution to form the solution to be released to heat.
Centrifugal separation tower
Here the flue gas carries a large amount of water vapor through this water separation system, which reduces the amount of steam carried to the chimney into the environment.
Suction fan
It works to overcome the resistance of exhaust gas on the smoke path from the furnace to the chimney, creating vortex in the device to remove dry ash and create negative pressure in primary and secondary combustion chambers.
Flue exhaust
Clean air after exiting the 2nd level absorption tower will be sucked into a exhaust pipe of 25.5m high to disperse into the environment.
3.2. System of washing packaging, drum barrel
Function: Wash all kinds of chemicals on the drum barrel and then reuse.
Capacity: 3 tons / day.
Process explanation
Check the inside of the drum barrel and proceed with the inclined slope of the tanks containing the residual chemicals. Then the barrel was taken away and rinsed.
Put the drum barrel on the drum shaking machine, put the motorcycle chain / pedal into the barrel so that when shaking the drum barrel, it will have a scrubbing effect.
Add 20 liters of caustic soda 20% or 5 liters of acetone to the container, tighten the lid. Turn on shaking mode for about 10 minutes.
Remove caustic soda or acetone into the container for circulation.
Transfer the drums that have been rinsed with chemicals to the washing machine in the drum barrel to wash the barrel with clean water. Drums after washing are gathered in storage for reuse or recycling.
For drums with a lot of sandy soil, dirt, the crust is cleaned by a system of sprinklers to clean before cleaning with a washing machine.
- SYSTEM CLAMPING BY CONCRETE (2019-12-14 08:08:48)
- SOLID SYSTEM (2019-12-14 08:06:35)
- WASTE WATER TREATMENT SYSTEM (2019-12-14 08:07:32)